Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
300~10000ppm CH4 Methane Gas Sensor For Domestic Gas Leakage Detectors

300~10000ppm CH4 Methane Gas Sensor For Domestic Gas Leakage Detectors

  • High Light

    10000ppm Methane Gas Sensor

    ,

    300ppm Methane Gas Sensor

    ,

    CH4 methane gas detector sensor

  • Name
    Methane Gas Sensor
  • Range
    300-10000ppm
  • Life
    10 Years
  • Type
    Semiconductor
  • Target Gas
    Methane/CH4
  • Power Consumption
    ≤400mW
  • Loop Voltage
    ≤24V DC
  • Application
    Domestic Gas Leakage Detectors
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX1014
  • Minimum Order Quantity
    1
  • Price
    Negitionable
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

300~10000ppm CH4 Methane Gas Sensor For Domestic Gas Leakage Detectors

300~10000ppm Methane Gas Sensor For Domestic Gas Leakage Detectors

 

Methane Gas Sensor Principle Introduction:

 

The sensing material of Methane Gas Sensor is tin dioxide SnO2, which has low conductivity in clean air. When the combustible gas exists, the conductivity of the sensor will be raise according to the gas concentration goes up. Through a simple circuit, to convert the changes of conductivity to correspond to the gas concentration.
Methane Gas Sensor has high sensitivity to methane, propane butane etc. combustible gas. The sensor can work in high temperature. It is low cost sensor and can be used in different applications.

 

Methane Gas Sensor Feature:

 

* High sensitivity to methane
* Long life and low cost
* Fast response and recovery

 

Methane Gas Sensor Technical Parameters :

 

Item Specification
Target Gas Methane /CH4
Measurement Range 300~10000ppm(CH4)
Heater Voltage(Vh) 5V±0.1V AC or DC
Loop Voltage ≤24V DC
Heater Resistance(Rh) 29Ω±3Ω(Room temperature)
Heater Power Consumption(Ph) ≤950mW
Sensitivity Rs(in air)/Rs(5000ppm CH4)≥ 5
Concentration Slope(α) ≤0.6(R5000ppm/R1000ppm CH4)
Output In Target Gas 2.5~4V(in 5000ppm CH4)
Testing Condition 20℃±2℃;55%±5%RH
Oxygen concentration in used place 21%, no less than 18%,If used in low oxygen concentration, pleasure contact for detail
Life Expectancy 10 years

 

Application

 

Liquefied petroleum gas, natural gas, coal gas monitoring device suitable for home or industrial. Excellent resistance to
alcohol, smoke interference ability