Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
0~1000ppm Electrochemical CO Gas Sensor For Underground Parking

0~1000ppm Electrochemical CO Gas Sensor For Underground Parking

  • High Light

    CO Gas Sensor For Underground Parking

    ,

    1000ppm Electrochemical CO Gas Sensor

    ,

    Underground Parking carbon monoxide gas sensor

  • Principle
    Electrochemical
  • Range
    0~1000ppm
  • Target Gas
    CO/Carbon Monoxide
  • Lifetime
    8 Years
  • Resolution
    0.5 Ppm
  • Repeatability
    ±2%
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX8015
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

0~1000ppm Electrochemical CO Gas Sensor For Underground Parking

MIX8015 0~1000ppm Electrochemical Carbon Monoxide(CO) Gas Sensor For Underground Parking

Principle Introduction:


MIX8015 Carbon Monoxide(CO) Gas Sensor is a battery operable electrochemical carbon monoxide sensor developed by Mixsen. Carbon monoxide and oxygen on the working electrode and counter electrode are subjected to oxidation-reduction reaction correspondingly. This produces the electric current. The current is directly proportional to the concentration of carbon monoxide and following the Faraday’s law. Through measure the current to get the concentration of carbon monoxide.

 

Feature:

 

High selectivity and sensitivity to CO ,High accuracy ,Linear output ,Long life ,Environmental protection design

 

Application:


Residential and commercial co gas detection

Industrial co gas monitors 

Indoor underground parking

Houseboat and moto home 

Fire detection 

Ventilation control

Domestic generator

 

Technical Parameters :

 

Item Specification
Target Gas Carbon monoxide
Measurement Range 0 ~ 1000 ppm
Maximum Overload 2000 ppm
Output Current 1.5-3.5 nA/ppm
Repeatability ±2%
Resolution 0.5 ppm
Response Time(T90) < 60 seconds
Long Term Output Drift < 2% /month
Life time 8 years
Operating Temperature Range -20 ~ 50˚c
Operating Humidity Range 15 ~ 90% RH
Operating Pressure Range 0.1mpa±10%
Recommended Load Resistor 1kΩ
Bias Voltage Not required


Operating Note:

 

* When soldering the metal ribbons, the soldering tin was forbidden to contact with the sensor.
* Aging the sensor no less than 30 mins before operation;
* Keeping the sensor out of the volatile solvent.
* Prohibit storage and operating the sensor in acidic or alkaline
environment.