Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX2801 Industrial Electrochemical Toxic Gas Detection Sensor Module For Industrial Gas Detector/

MIX2801 Industrial Electrochemical Toxic Gas Detection Sensor Module For Industrial Gas Detector/

  • High Light

    NH3 chlorine detector sensor

    ,

    10mA chlorine detector sensor

    ,

    NH3 chlorine dioxide sensor

  • Target Gas
    CO、H2S、O2、NH3、NO2、O3、N2、SO2、CL2、HF、H2、PH3、HCL Etc.
  • Range
    /
  • Life
    2 Years
  • Type
    Electrochemical
  • Output
    UART & Analog Voltage
  • Size
    ø23.5mm*24.5mm
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX2801
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX2801 Industrial Electrochemical Toxic Gas Detection Sensor Module For Industrial Gas Detector/

MIX2801 Industrial Electrochemical Toxic Gas Detection Sensor Module For Industrial Portable & Fixed Toxic Gas Detector/Alarms

Principle Introduction:

 

MIX2801 is a general-purpose and high-performance gas detection module with electrochemical gas sensors. It uses three electrodes, electrochemical gas sensor and high-performance micro-processor. By installing different gas sensor, the module could detect relevant gas. It is with built-in temperature sensor to make temperature compensation, which makes it could detect the gas concentration accurately.
It has the digital output and analog voltage output at the same time which facilities the usage and calibration and shorten the development period. It is a combination of mature electrochemical detection principle and sophisticated circuit design, to meet customers’ different detection needs.

 

Feature:

 

* High sensitivity and Accuracy to toxic gas
* Long life, low power consumption
* Good stability for toxic gas
* UART and analog voltage signal output

 

Application:

 

* Portable toxic gas detector
* Fixed toxic gas alarm and detector

 

 

Technical Parameters :

 

Item Specification
Target Gas CO,H2S,O2,NH3,NO2,O3,N2,SO2,CL2,HF,H2,PH3,HCL etc.
Measurement Range Refer table 2
Operating Voltage DC 5±0.1V DC
Operating Current < 10 mA
Output UART(TTL electrical Level, 3V)
Analog voltage(refer table 2 for sensor original amplifying signal)
Operating Conditions -20~25℃/15~90%RH(no condensation)
Storage Conditions -20~50℃/15~90%RH(no condensation)
Size ø23.5mm*24.5mm
Life Expectancy 2 years(in air)

 

Measurement Range and signal output:(Table 2)

Target Gas CO O2 NH3 H2S NO2 HCL
Measurement Range (0-1000)ppm (0-25)%VOL (0-100)ppm (0-100)ppm (0-20)ppm (0-10)ppm
Resolution 1 ppm 0.1%VOL 1 ppm 1 ppm 0.1 ppm 0.1 ppm
Output in the air(V0) (0.3-3)V (3-0.3)V (0.3-3)V (3-0.3)V (0.3-3)V (0.3-3)V
Response Time(T90) 30S ≤15S ≤150S 30S 30S ≤60S

 

Target Gas H2 PH3 SO2 O3 CL2 HF
Measurement Range (0-1000)ppm (0-1000)ppm (0-20)ppm (0-10)ppm (0-10)ppm (0-10)ppm
Resolution 1 ppm 0.1 ppm 0.1 ppm 0.1 ppm 0.1 ppm 0.1 ppm
Output in the air(V0) (0.3-3)V (0.3-3)V (0.3-3)V (3-0.3)V (3-0.3)V (0.3-3)V
Response Time(T90) ≤120S 30S 30S ≤120S 30S ≤60S