Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX2111D-LEL Digital Output Methane/CH4 Gas Detection Sensor Module For Gas Alarm

MIX2111D-LEL Digital Output Methane/CH4 Gas Detection Sensor Module For Gas Alarm

  • High Light

    LEL Explosive Gas Detection Sensor

    ,

    UART Gas Detection Sensor

    ,

    LEL combustible gas sensor

  • Life
    ≥10 Years
  • Type
    Semiconductor
  • Target Gas
    Combustible Gas, Alkanes, Co,ch4
  • Weight
    20g
  • Size
    24*20*15mm(L*W*H)
  • Output
    0.00~100.0%LEL
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX2111D
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX2111D-LEL Digital Output Methane/CH4 Gas Detection Sensor Module For Gas Alarm

MIX2111D-LEL Digital Output Methane/CH4 Gas Detection Module For Combustible And Explosive Gas Monitoring Alarm

Principle Introduction:

 

MIX2111D-LEL adopts semiconductor gas sensor, featuring high sensitivity, small size and long life. It also adopts digital UART interface output with user calibration function. The sensor has high sensitivity to VOCs such as formaldehyde, benzene, carbon monoxide, ammonia, hydrogen, alcohol, cigarette smoke, perfume etc., methane and propane. The module was already aged, debugged and calibrated, it has good consistency and high sensitivity.

 

Feature:

 

* High sensitivity to combustible gas
* Low cost, long life
* Good stability
* Simple application circuit

 

Application:

 

* Combustible gas alarm/detector
* Combustible and explosive gas monitoring device

 

Technical Parameters :

 

Item Specification
Target Gas formaldehyde, benzene, carbon monoxide, ammonia, hydrogen, alcohol, cigarette smoke, perfume
Operation voltage 4.8-5.2V DC
Operation Current < 80mA average
Preheating Time ≤ 3 minutes
response time(T90) <20 seconds
recovery time <60 seconds
Long Term Sensitivity Drift ≤1%/year
Digital output 0.00~100.0%LEL
Communication Interface 5V electrical level TTL
Operation Conditions 0~50/15~90%RH (no condensation)
Storage Conditions -20~50/0~60%RH (no condensation)
Size 24*20*15mm(L*W*H)
Weight ≤ 20g
Life Expectancy ≥ 10 years