Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX1005 CH4 & LPG Semiconductor Combustible Gas Detection Sensor Range 300~10000ppm

MIX1005 CH4 & LPG Semiconductor Combustible Gas Detection Sensor Range 300~10000ppm

  • High Light

    300ppm propane gas leak detector

    ,

    LPG propane gas leak detector

    ,

    LPG combustible gas sensor

  • Range
    300-10000ppm
  • Life
    10 Years
  • Type
    Semiconductor
  • Target Gas
    Combustible Gas, LPG
  • Power Consumption
    ≤950mW
  • Testing Condition
    20℃±2℃;55%±5%RH
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX1005
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX1005 CH4 & LPG Semiconductor Combustible Gas Detection Sensor Range 300~10000ppm

MIX1005 CH4 & LPG Combustible Gas Detection Sensor Range 300~10000ppm For Gas Leakage Detectors And Alarms

Principle Introduction:

 

The sensing material of MIX1005 Combustible (CH4 & LPG) Gas Detection Sensor is tin dioxide SnO2, which has low conductivity in clean air. When the combustible gas exists, the conductivity of the sensor will be raise according to the gas concentration goes up. Through a simple circuit, to convert the changes of conductivity to correspond to the gas concentration.
MIX1005 Combustible (CH4 & LPG) Gas Sensor has high sensitivity to LPG (C3H8) The sensor can work in high temperature. It is low cost sensor and can be used in different applications.

 

Feature:

 

* High sensitivity to wide range of LPG
* Long life and low cost
* High ant seismic

 

Application:


* Domestic gas leakage detectors
* Portable gas detectors

 

Technical Parameters :

 

Item Specification
Target Gas Combustible gas, LPG
Measurement Range 300~10000ppm(CH4)
Heater Voltage(Vh) 5V±0.1V AC or DC
Loop Voltage ≤24V DC
Heater Resistance(Rh) 29Ω±3Ω(Room temperature)
Heater Power Consumption(Ph) ≤950mW
Sensitivity Rs(in air)/Rs(5000ppm CH4)≥ 5
Concentration Slope(α) ≤0.6(R5000ppm/R1000ppm CH4)
Output In Target Gas 2.5~4V(in 5000ppm CH4)
Testing Condition 20℃±2℃;55%±5%RH
Oxygen concentration in used place 21%, no less than 18%,If used in low oxygen concentration, pleasure contact for detail
Life Expectancy 10 years