Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX8417 Hydrogen Sulfide Gas Sensor 2000ppm Electrochemical Gas Sensor

MIX8417 Hydrogen Sulfide Gas Sensor 2000ppm Electrochemical Gas Sensor

  • High Light

    MIX8417 Hydrogen Sulfide Gas Sensor

    ,

    2000ppm Hydrogen Sulfide Gas Sensor

    ,

    2000ppm electrochemical gas sensor

  • Target Gas
    Hydrogen/H2
  • Range
    0 ~ 1000ppm
  • Life
    2 Years
  • Type
    Electrochemical
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX8417
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX8417 Hydrogen Sulfide Gas Sensor 2000ppm Electrochemical Gas Sensor

MIX8417 Electrochemical 0 ~ 1000ppm Hydrogen(H2) Gas Detection Sensor

Principle Introduction:

 

MIX8417 Hydrogen(H2 ) gas sensor is an electrochemical sensor developed by Mixsen. It uses the principle of electrochemistry. There is a reference electrode inside the sensor, which greatly improves the stability of the sensors. When the sensor senses the hydrogen, the working electrode and the counter electrode react with the redox reaction, through measure the current to get the concentration of hydrogen.

 

Feature:


High selectivity & sensitivity to H2
High accuracy
Linear output

high-precision
 

 

Application:

 

Industrial monitors leakage detection
Transformer hydrogen detection

Industrial H2 gas detector

industrial hydrogen monitor

 

Technical Parameters :

 

Item Specification
Target Gas hydrogen
Measurement Range 0~1000 ppm
Maximum Overload 2000 ppm
Sensitivity 10± 5 μA/ppm
Repeatability ±2%
Response Time(T90) < 90 Seconds
Resolution 2 ppm
Long Term Output drift <2% per month
Life Expectancy(in air) 2 Years
Operating Temperature Range -20 ~ 50˚C / 15~90% RH
Operation Press 0.1MPa ± 10%
Bias Voltage Not required
Note: All measurements were taken at 20˚C, 50%RH at 1013hPa