Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
Hydrogen Sulfide H2S Toxic Gas Sensor 100ppm Used For Comprehensive Underground Corridor Monitoring

Hydrogen Sulfide H2S Toxic Gas Sensor 100ppm Used For Comprehensive Underground Corridor Monitoring

  • High Light

    H2S Toxic Gas Sensor

    ,

    100ppm Toxic Gas Sensor

    ,

    100ppm h2s gas sensor

  • Target Gas
    Hydrogen Sulfide/H2S
  • Range
    0~100ppm
  • Life
    2 Years(in Air)
  • Type
    Electrochemical
  • Response Time
    <60 Seconds
  • Sensitivity
    0.6-1.0uA/ppm
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX8416
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

Hydrogen Sulfide H2S Toxic Gas Sensor 100ppm Used For Comprehensive Underground Corridor Monitoring

MIX8416 Electrochemical Hydrogen Sulfide(H2S) Gas Detection Sensor For Industrial Gas Leak Monitors 0~100ppm

Principle Introduction:

 

MIX8416 is an electrochemical hydrogen sulfide (H2S) sensor developed by Mixsen. It uses the principle of electrochemistry, the hydrogen sulfide gas undergoes a redox reaction under the catalyst condition. This produces the electric current. The current is directly proportional to the concentration of hydrogen sulfide . Through measure the current to get the concentration of hydrogen sulfide

 

Feature:


High selectivity for H2S

High accuracy for hydrogen sulfide

Linear output 

Environmental protection design

Good anti-interference ability

Excellent repeatability and stability

 

Application:


Industrial toxic gas monitors

leakage h2s gas detection 

Environmental protection field 

The Comprehensive Underground corridor

 

Technical Parameters :

 

Item Specification
Target Gas hydrogen sulfide/h2s
Measurement Range 0-100 ppm
Maximum Overload 200 ppm
Sensitivity 0.6- 1.0 µA/ppm
Response Time(T90) ≤60 Seconds
Repeatability ±2%
Long Term Output Drift <2﹪/month
Lifetime 2 years
Operating Temperature Range -20 ~ 50˚c
Resolution 0.5 ppm
Operating Humidity Range 15 ~ 90% RH,no condensing
Bias Voltage Not required