Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX8012 CO Gas Sensor 1000ppm Electrochemical Carbon Monoxide Gas Sensor

MIX8012 CO Gas Sensor 1000ppm Electrochemical Carbon Monoxide Gas Sensor

  • High Light

    1000ppm Electrochemical CO Gas Sensor

    ,

    MIX8015 CO Gas Sensor

    ,

    1000ppm electrochemical gas detector

  • Principle
    Electrochemical
  • Range
    0~1000ppm
  • Target Gas
    CO/Carbon Monoxide
  • Lifetime
    7 Years
  • Resolution
    0.5ppm
  • Sensitivity
    >0.015uA/ppm
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX8012
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX8012 CO Gas Sensor 1000ppm Electrochemical Carbon Monoxide Gas Sensor

High Precision And Sensitivity Electrochemical Carbon Monoxide(CO) Gas Detection Sensor

Principle Introduction:

 

Carbon Monoxide ( Co ) gas sensor is electrochemical gas sensor,the concentration of the gas could be get by measuring value of current.We have different types of CO sensors, except the sensor, we also have modules and we can supply one-stop gas sensor solutions.The most hotsale type of co sensor is:MIX8012,MIX8011,MIX8015,etc.The life of the Carbon Monoxide (co) gas sensor are 3 years,7years,8years,10years.So just tell us your detail need,we can meet your different needs and send you price asap.

 

Feature:

 

Low power consumption;
High precision;
High sensitivity;
Wide linear range;

Long service life
Temperature compensation
Anti-vapor interference
Good anti-interference ability;
 

 

Application:

 

Residential Carbon Monoxide detector and alarm

Commercial Carbon Monoxide ( CO ) detector and alarm

Fire detection; Ventilation control.

 

Technical Parameters :

 

Item Specification
Measurement Range 0-1000ppm
Maximum Overload 2000ppm
Sensitivity >0.015uA/ppm
Resolution 0.5ppm
Response Time(T90) <50s
Recommended Load Resistor 200Ω
Repeatability <3﹪ Output value
Stability(/Year) <10﹪
Output Linearity Linear
Zero Drift(-20℃~40℃) ≤10ppm
Storage Temperature -20℃ ~ 50℃
Storage Humidity 15﹪ ~ 90﹪Rh
Pressure Range Normal atmosphere ±10%
Anticipated Using Life 7 Years



Operating Note:

 

* Forbidden tin soldering before usage.
* Aging for more than 48 hours before using.
* Sensor’s pins can’t be broke off or bent.
* Don’t disassemble the sensor to avoid the damage caused by electrolyte leakage.
* Avoid contacting organic solvent (including silicone rubber and other adhesive), coatings, medicine, oil and high concentration gases.
*All the electrochemical sensors shall not be encapsulated completely by resin materials, and shall not immerse in pure oxygen environment,   otherwise, it will damage the function of sensor
* All electrochemical sensors shall not be applied in corrosive gas environment, or the sensor will be damaged
* Zero calibration should be finished in clean air.
* During test and usage, sensors should avoid the gas inflow vertically
* The side for inflow can’t be choked and polluted.
* The laminating film above the sensor surface can’t be uncovered and damage.
* Excessive impact or vibration should be avoided
* It takes some time for the sensor to return to normal state after it is applied in high concentration gas.
* Working electrode and reference electrode of the sensor shall be in short circuit when stored
* Prohibit to use the hot cement or sealant of which the curing temperature is higher than 80℃ to make the capsulation for the sensor.
*Prohibit storage and usage for long time in alkaline gases with high concentration.
*Do not use the sensor when the shell is damaged.