Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
Air Quality Monitoring NDIR CO2 Detection Sensor 400ppm Carbon Dioxide Gas Sensor

Air Quality Monitoring NDIR CO2 Detection Sensor 400ppm Carbon Dioxide Gas Sensor

  • High Light

    MIX6013 NDIR Co2 Detection Sensor

    ,

    9.2mm Co2 Detection Sensor

    ,

    MIX6013 carbon dioxide gas sensor

  • Target Gas
    Carbon Dioxide Gas
  • Range
    400-5000PPM
  • Type
    NDIR
  • Size
    39x20x9.2mm
  • Output
    UART, PWM
  • Life
    >5 Years
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX6013
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

Air Quality Monitoring NDIR CO2 Detection Sensor 400ppm Carbon Dioxide Gas Sensor

Air Quality Monitoring Using NDIR Carbon Dioxide(CO2) Gas Detection Sensor 400-5000PPM

 

Principle Introduction:

 

The carbon dioxide gas sensor (hereinafter referred to as the sensor) is a general intelligent small sensor. It uses the principle of non dispersive infrared (NDIR) to detect the CO2 in the air, which has the characteristics of good selectivity, oxygen free dependence and long life; Built in temperature compensation; At the same time, it has serial port output, analog output and PWM output, which is convenient to use. The sensor is a high performance sensor which combines the mature infrared absorption gas detection technology with the design of precise optical circuit and excellent circuit.

 

Feature:

 

Provide UART, DAC, PWM waveform output mode
Anti water vapor interference, no poisoning
Excellent stability and long service life
Temperature compensation, excellent linear output

 

Application:

 

indoor &outdoor Air quality monitoring equipment, fresh air system, air purification equipment, HVAC

 

Technical Parameters :

 

 

Item Specification
Measurement Range 400~5000ppm(Other range available)
Operating Principle (NDIR)
Power Supply 4.5~5.5V DC
Operating Current 120mA peak, 20mA average
Accuracy ±(50ppm+5% of reading)
Warm Up Time 3 minutes
Response Time T90 < 120 seconds
Time Between Detection 2 seconds
Operating Conditions 050/090%Rh(No condensation)
Storage Conditions - 20~60℃/0~90%Rh(No condensation)
UART (TTL interface level 3.3V)
Communication Interface PWM
Vout (Analog output interface)
Size 39 X 20 X 9.2 (mm)
Weight Approx.5g
Using Life >5 years