Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX6071 High Accuracy Laser Dust Particle Matter PM2.5 Sensor For Fresh Air Systems

MIX6071 High Accuracy Laser Dust Particle Matter PM2.5 Sensor For Fresh Air Systems

  • High Light

    Volatile Pm2.5 Dust Sensor

    ,

    Organic Pm2.5 Dust Sensor

    ,

    PM10 Volatile air pollution detector

  • Target Gas
    PM1.0, PM2.5, PM10
  • Range
    0.3μm~10μm
  • Type
    Laser
  • Size
    48x37x12mm
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX6071
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX6071 High Accuracy Laser Dust Particle Matter PM2.5 Sensor For Fresh Air Systems

MIX6071 High Precision Laser Dust Particle Matter Sensor For Air Purifier Monitor

 

Principle Introduction:

 

MIX6071PM2.5 dust sensor is a miniaturized laser-type dust sensor. It uses the principle of optical scattering to accurately detect and count the number of suspended particles of different sizes in the air per unit volume. The particles are achieved through mathematical algorithms and scientific calibration. Real-time output of PM2.5 mass concentration.

 

Feature:


Small size 

Light weight
12mm ultra-thin design

Quick response and high accuracy
A variety of air inlet and outlet directions to meet different installation needs

 

Application:

 

HAVC refrigeration , Environment Monitoring,Air purifiers, air conditioners, PM2.5 detectors, fresh air systems, air detectors, etc.

 

Technical Parameters :

 

 

Item Specification
Measurable Dust Size 0.3μm~10μm
Measurement Range 0-1000ug/m³
Resolution 1ug/m³
Working Condition -15℃~60℃, 0-95%RH(non-condensing)
Storage Condition -30℃~70℃, 0-95%RH(non condensing)
Measurement Accuracy(PM1.0 and PM2.5) 0~80μg/m³, ±8μg/m³
80μg/m³ ~ 600μg/m³,± 15%
Condition:23±3℃,50±10%RH
Reference Instrument:PULSE Standard
Dust Source:Cigarette(8mg)
Measurement Accuracy(PM10) 0~100μg/m³, ±25μg/m³
100μg/m³ ~ 600μg/m³,± 25%
Condition:23±3℃,50±10%RH
Reference Instrument:PULSE Standard
Dust Source: Cigarette(8mg)
Output Interval 1s
Time of first Reading ≤5s
Power Supply DC 5V±0.3V,Ripple wave<50mV
Working Current ≤90mA
Standby Current ≤50μA
Dimension 48x40x12mm
Digital output mode UART TTL 3.3V
MTTF 30000 Hours