Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX6070 Air Quality PM 2.5 PM10 Laser Dust Sensor VOC Air Pollution Monitoring

MIX6070 Air Quality PM 2.5 PM10 Laser Dust Sensor VOC Air Pollution Monitoring

  • High Light

    mix6070 VOC Pm2.5 Dust Sensor

    ,

    PM10 Pm2.5 Dust Sensor

    ,

    mix6070 air quality gas sensor

  • Target Gas
    PM1.0, PM2.5, PM10
  • Range
    0.3μm~10μm
  • Type
    Laser
  • Size
    48x37x12mm
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX6070
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX6070 Air Quality PM 2.5 PM10 Laser Dust Sensor VOC Air Pollution Monitoring

MIX6070 Air Quality PM 2.5 PM10 PM1 Laser Dust Particulate Matter VOC Air Pollution Gas Sensor

 

Principle Introduction:


MIX6070 Laser Dust Sensor is used to measure the dust particle (Size: 0.3μm~10μm) in the environment and output the dust density real-time value (μg/m³) of PM1.0, PM2.5, PM10. The body of the sensor is designed with ultra-thin (12mm) structure for easy and diverse installation, full metal cover for electrical shielding and built-in advanced algorithm based on optical scattering technology with light source of Laser for accurate and steady output.

 

Feature:


Small size , Light weight , Easy to install , Simple maintenance

 

Application:


Air purifier , Air Quality Monitor , HAVC refrigeration , Environment Monitoring

 

Technical Parameters :

 

 

Item Specification
Measurable Dust Size 0.3μm~10μm
Measurement Range 0-600ug/m³
Resolution 1ug/m³
Working Condition -15℃~50℃, 0-95%RH(non-condensing)
Storage Condition -30℃~70℃, 0-95%RH(non condensing)
Measurement Accuracy(PM1.0 and PM2.5) 0~80μg/m³, ±8μg/m³
80μg/m³ ~ 600μg/m³,± 15%
Condition:23±3℃,50±10%RH
Reference Instrument:PULSE Standard
Dust Source:Cigarette(8mg)
Measurement Accuracy(PM10) 0~100μg/m³, ±30μg/m³
100μg/m³ ~ 600μg/m³,± 30%
Condition:23±3℃,50±10%RH
Reference Instrument:PULSE Standard
Dust Source: Cigarette(8mg)
Output Interval 1s
Time of first Reading ≤5s
Power Supply DC 5V±0.3V,Ripple wave<50mV
Working Current ≤90mA
Standby Current ≤50μA
Dimension 48x37x12mm
Digital output mode UART TTL 3.3V
MTTF 30000 Hours