MIX1002B semiconductor Combustible And Smoke Gas Detection Sensor For Fire Gas Alarm

MIX1002B semiconductor Combustible And Smoke Gas Detection Sensor For Fire Gas Alarm

  • High Light

    10000ppm c3h8 methane gas sensor

    ,

    MIX1002B c3h8 methane gas sensor

    ,

    mixsen 1002B methane gas sensor

  • Range
    300-10000ppm
  • Life
    10 Years
  • Type
    Semiconductor
  • Target Gas
    Combustible Gas, Smoke
  • Sensitivity
    Rs(in Air)/Rs(2000ppm C3H8)≥ 5
  • Load Resistance
    Adjustable
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX1002B
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX1002B semiconductor Combustible And Smoke Gas Detection Sensor For Fire Gas Alarm

MIX1002B Combustible and Smoke Gas Detection Sensor

Principle Introduction:


The sensing material of MIX1002B is tin dioxide SnO2, which has low conductivity in clean air. When the combustible/LPG gas exists, the conductivity of the sensor will be raise according to the gas concentration goes up. Through a simple circuit, to convert the changes of conductivity to correspond to the gas concentration.

MIX1002B Combustible and Smoke Gas Sensor has high sensitivity to propane butane etc. combustible gas. The sensor can work in high temperature. It is low cost sensor and can be used in different applications.

 

Feature:

 

High sensitivity to methane
Low power consumption
Long life and low cost
Fast response and recovery

 

Application:


* Domestic gas leakage detectors
* Portable gas detectors

 

Technical Parameters :

 

Item Specification
Target Gas Combustible gas, smoke
Measurement Range 200~10000ppm(Combustible gas)
Heater Voltage(Vh) 5V±0.1V AC or DC
Loop Voltage ≤24V DC
Load Resistance Adjustable
Heater Resistance(Rh) 629Ω±3Ω(Room temperature)
Heater Power Consumption(Ph) ≤950mW
Sensitivity Rs(in air)/Rs(2000ppm C3H8)≥ 5
Output In Target Gas 2.5~4V(in 2000ppm C3H8)
Testing Condition 20℃±2℃;65%±5%RH
Oxygen concentration in used place 21%, no less than 18%,If used in low oxygen concentration, pleasure contact for detail
Life Expectancy 10 years