Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX8018 CO Gas Sensor 0-1000ppm Electrochemical Carbon Monoxide Detector Sensor

MIX8018 CO Gas Sensor 0-1000ppm Electrochemical Carbon Monoxide Detector Sensor

  • High Light

    MIX8018 industrial gas sensor

    ,

    1000ppm industrial gas sensor

    ,

    MIX8018 electrochemical carbon monoxide detector

  • Principle
    Electrochemical
  • Range
    0~1000ppm
  • Target Gas
    CO/Carbon Monoxide
  • Lifetime
    7 Years
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX8018
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX8018 CO Gas Sensor 0-1000ppm Electrochemical Carbon Monoxide Detector Sensor

MIX8018 CO Gas Sensor 0-1000ppm Electrochemical Carbon Monoxide Detector Sensor

Principle Introduction:

 

MIX8018 Carbon Monoxide (CO) gas Sensor is a battery operable electrochemical gas sensor developed by Mixsen. Carbon monoxide and oxygen on the working electrode and counter electrode are subjected to oxidation-reduction reaction correspondingly. This produces the electric current. The current is directly proportional to the concentration of carbon monoxide and following the Faraday’s law. Through measure the current to get the concentration of carbon monoxide.

 

Feature:

 

High selectivity and sensitivity to CO gas, High accuracy ,Linear output ,Long life ,Environmental protection design

 

Application:

 

Residential and commercial co gas alarm ,Industrial monitors ,Indoor underground parking ,Houseboat and moto home ,Fire detection ,Ventilation control ,Domestic generator

 

Technical Parameters :

 

Item Specification
Target Gas Carbon monoxide
Measurement Range 0 ~ 1000 ppm
Maximum Overload 2000 ppm
Output Current 1.5-3.5 nA/ppm
Repeatability ±2%
Resolution 0.5 ppm
Response Time(T90) < 60 seconds
Long Term Output Drift < 2% /month
Lifetime 7 years
Operating Temperature Range -20 ~ 50˚c
Operating Humidity Range 15 ~ 90% RH
Operating Pressure Range 0.1mpa±10%
Recommended Load Resistor 1kΩ
Bias Voltage Not required



Operating Note:

 

When soldering the metal ribbons, the soldering tin was forbidden to contact with the sensor.
* Aging the sensor no less than 30 mins before operation;
* Keeping the sensor out of the volatile solvent.
* Prohibit storage and operating the sensor in acidic or alkaline environment.