Shenzhen Mixsen Electronics Co.,Ltd. 86-185-6625-9936 sales@mixsen.com
MIX2810 CO Gas Sensor Module 500ppm Used For Gas Water Heater

MIX2810 CO Gas Sensor Module 500ppm Used For Gas Water Heater

  • High Light

    MIX2810 T90 CO Gas Sensor

    ,

    500ppm Module CO Gas Sensor

    ,

    MIX2810 500ppm gas sensor module

  • Principle
    Electrochemical
  • Range
    0~500ppm
  • Target Gas
    CO/Carbon Monoxide
  • Lifetime
    3 Years
  • Place of Origin
    Zhengzhou,China
  • Brand Name
    Mixsen
  • Model Number
    MIX2810
  • Minimum Order Quantity
    1
  • Packaging Details
    Inner packaging: foam cushion Outer packaging: carton
  • Delivery Time
    within 3 working days after payment
  • Supply Ability
    10,000/day

MIX2810 CO Gas Sensor Module 500ppm Used For Gas Water Heater

MIX2810 CO Gas Sensor Module 500ppm Used For Gas Water Heater

MIX2810 Carbon Monoxide(CO) is a generality electrochemical carbon monoxide detection module. It utilizes electrochemical principle to detect CO gas in air which makes the module with high selectivity and stability. Each module has UART, can be calibrated. It is easy to connect with the customer product.

 

Feature:

 

Lower power consumption , High sensitivity , Multiple interfaces , Long life

 

Application:

 

Indoor CO detection ,Smart home , Gas water Heater , Automatic fans

 

Technical Parameters :

 

Item Specification
Measurement range 0~500ppm
Resolution 1 ppm
Sensor Electrochemistry
Working Voltage 4.5~5.5V DC
Working Current <10mA average
Accuracy ±10 ppm(calibration concentration)
Preheating Time 30 Seconds
Response Time T90<30s
Inspection Interval 1 Second
Working Conditions -10~55℃/0-90%RH(no condensation)
Storage Conditions -10~55℃/0~90%RH(no condensation)
Communication Interface UART (3.3V electrical level)
Size 39×17×15.4mm(L×W×H)
Anticipated Using Life 3 years



Operating Note:

 

* When soldering the metal ribbons, the soldering tin was forbidden to contact with the sensor.
* Aging the sensor no less than 30 mins before operation;
* Keeping the sensor out of the volatile solvent.
* Prohibit storage and operating the sensor in acidic or alkaline
environment.